Skip to content

Unequal Flange Bays & Accessories / Unequal Flange Bays

Unequal Flange Bays

R4R SERIES (SEISMIC ZONE 2)

R3R SERIES (SEISMIC ZONE 4)

PHYSICAL DESCRIPTION

7Environment: All 7UEF Bay configurations contain a welded steel frame structuralncomponent. The welded frame consists of a 26or 22wide x 10deep base, two 5deep x 84high unequal flange uprights and a top channel. There is a 6high guard box located either on the closed duct side of the uprights (large flange) or the open duct side (small flange). Both flanges of the uprights are drilled and tapped for either 1.75(1.25 -.50 ctrs) or 2(1”ctrs) mounting patterns. The floor mounting holes in the base meet the requirements of NEBS GR-63. Standard finishes are Telco Gray, Network Blue or Off-White. 

26wide bays are nominally referred to as 23bays.

22wide bays are nominally referred to as 19bays. 

8′, 9′, 10& 11′-6Environments: The most common method to achieve these taller environments is to utilize a 7′ network bay with an extender. Moreng extenders come in several different heights (12″, 24″, 36″, 54and 56″). The extender bolts to the top of the network bay and should be supported to the overhead grid. In seismic applications, the extender is designed not to accept equipment. The other option to reach these desired heights is to install a network bay that is made to the specific height. 

Foot Print Depths: Rear Guard Rail Kits and Front Guard Box Extensions are added to the welded 10deep frame for building out to the required footprint depths, which the equipment being mounted requires for protection.

NEBS EARTHQUAKE & VIBRATION CERTIFICATION – (23BAYS ONLY) 

R4R Series Bay: Our 7UEF Bays have been tested and certified to NEBS GR-63 Level 2 (seismic zones 0-2) requirements. The bays were tested for an equally distributed equipment load of 500 pounds.

R3R Series Bay: Our 7UEF Network Bays have been tested and certified to NEBS GR-63 Level 3 (seismic zones 3 & 4) requirements. The bays were tested for an equally distributed equipment load of 500 pounds.

R7R Series Bay Extenders: Our 7Seismic Network Bay Extenders have been tested and certified to NEBS GR-63 Level 3 (seismic zones 3 & 4) requirements. The empty extender with 50# top load was mounted on top of a 7R7R bay, which contained an equally distributed equipment load of 520 #s. The bay extender is manufactured so that NO equipment can be mounted in it.

Click to Open Image and Zoom
ModelCategoriesPDF ImageFinishW x H (in.)Depth (in.)Add to Quote